Equipment Technical Specifications |
|
Model |
TS30S |
Picture |
|
Feed Capacity |
78 Liters for primary chamber |
Burning Rate |
Average 30 kgs per hour |
Burning Time per Feed |
0.5 hour |
Voltage |
220V |
Power |
0.5Kw |
Fuel |
Diesel oil |
Burner |
Diesel Oil Burner, 2 sets |
Feed Mode |
Manual |
Fuel consumption (Oil) |
Average 8 Kgs/Hour |
External Dimensions |
90 x 90 x 150cm (main body) |
Internal Dimensions |
Dia.50 x 40cm(Primary Chamber) |
Waste combustion chamber |
78Liters |
Post Combustion Chamber |
50Liters |
Oil Tank Capacity |
100 Liters |
Door Opening |
25 x 25cm |
Chimney |
3.0M |
Gross Weight |
1200kgs |
Chamber Material |
Refractory Concrete |
Max. Heat Value |
80,000Kcal/Hr. |
Operation Technical Specifications |
|
Chamber temperature |
8000C -10000C |
Chamber Anti-Rate |
13500C |
Residency time |
0.5 Sec. |
Burning efficiency |
>98% |
Waste Lower Calorific Power |
3000Kcal |
ways of disposing solid waste
HICLOVER Incinerator/Parts Range |
Main Feature |
Medical Waste Incinerators |
HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
Single Combustion Chamber |
Small, Cheap,10-20kgs/Hr. |
Three Combustion Chambers(Optional) |
3 Chambers for high risk waste |
Pet Cremation Equipment |
For Pet(small/big) Cremation Business |
Animal Incineration Equipment |
For other animal incineration |
effect of biomedical waste on human health
Items/Model |
TS100(PLC) |
TS150(PLC) |
TS300(PLC) |
TS500(PLC) |
Burn Rate (Average) |
100 kg/hour |
150 kg/hour |
300 kg/hour |
500 kg/hour |
Control Mode |
PLC Auto. |
PLC Auto. |
PLC Auto. |
PLC Auto. |
Combustion Chamber |
1200L |
1500L |
2000L |
3000L |
Internal Dimensions |
120x100x100cm |
150x100x100cm |
170x120x100cm |
210x120x120cm |
Secondary Chamber |
600L |
750L |
1000L |
1500L |
Smoke Filter Chamber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Feed Mode |
Manual |
Manual |
Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V |
Power |
1.38Kw |
1.69Kw |
2.57Kw |
4.88Kw |
Diesel Oil Consumption (kg/hour) |
Ave.20.4 |
Ave.24.2 |
Ave.33 |
Ave.44 |
Natural Gas Consumption (m3n/hour) |
Ave.24.5 |
Ave.29 |
Ave.39.6 |
Ave.52.8 |
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
200L |
300L |
500L |
500L |
Chimney |
10Meter |
10Meter |
14Meter |
14Meter |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
6000kg |
8500kg |
11000kg |
16000kg |
External Dimensions |
260x150x180cm |
300x160x190cm |
400x210x300cm |
450x210x300cm |
The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations.
“The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle.
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
2. Auto Roll Air Filter for Clean Room2021-02-21